Power Meters and Tranducers

 

 

 

2160-A (LED)

2160-A (LED)

2160-A Multifunction Power and Energy Meter

Applications for 2160 – A (LED)

  • Accuracy class 0.5s/0.2s as per IS14697/ IEC 62053-22
  • 4 lines 4 digit 0.4”LED display optional large multi-line backlit LCD panel
  • 100+ Electrical parameter display
  • Standard: Isolated RS485 (modbus-RTU protocol)
  • Standard: Pulse output
  • Total harmonic distortion (THD), maximum demand (optional)

EM 2140 Dual Source Energy Meter

Applications for EM 2140

  • Accuracy class 1.0 as per IS 13779/ IEC 62053-21
  • Compact flush panel mounting
  • Field programmable CT/PT ratio
  • Ultra bright 8 digit LED display 0.36” with auto scaling capability
  • Optional pulse output / relay output
  • Optional EB/DG dual source input
  • Isolated RS485 (Modbus-RTU protocol)
  • Password protection for set parameters
  • Permanent memory based energy storing along with other parameters like ON hour, load hour and power interruption count
EM 2140

EM 2140

PM 2140

PM 2140

PM 2140 Multifunction Meter

Applications for PM 2140

  • Energy accuracy class 1.0 as per IS 13779/ IEC 62053-21
  • Better than 0.5% accuracy for instantaneous parameters
  • Compact flush panel mounting
  • Field programmable CT/ PT ratio
  • Ultra bright 3 line 4 digit LED Display 0.4” for PM2140 with auto scaling capability
  • Optional analog output/ relay output
  • Isolated RS485 (Modbus-RTU protocol)
  • Password protection for set parameters
  • Permanent memory based energy storing along with other parameters like ON hour, load hour and power interruption count

Applications for energy meters

  • HT/LT panels
  • EMS system
  • Equipment efficiency
  • HVAC and building application

VAF 2310/ 2330 – V, A, F & VAF Indicator Range

Applications for VAF 2310, 2330

  • View 3 parameters (volt/ amp/ freq) in single meter
    (1 ph & 3 ph config)
  • Accuracy class 1.0
  • LED indicator for each parameter
  • ON hour/ run hour/ RPM (in 3 phase, 3 line)
  • Maximum current and voltage control through relay
    (optional)
  • Applications for VAF Indicator
  • Industrial control panel/ control relay panel
  • Test benches, lab equipment
VAF 2310/ 2330 – V, A, F & VAF Indicator Range

2310, 2330

Masibus AC Line Tranducers

Masibus AC Line Tranducers

AC Line Transducers

Applications for Tranducers

  • High accuracy class 0.25%
  • Confirms to IEC 60688
  • Range available: V/ I/ W/ VAR/ PF/ F
  • mA/mV/V output available (single/ dual)
  • 1 Ph and 3 Ph configuration available
  • Excellent long term stability
  • Low burden
  • Transient protected
  • Good isolation & impulse resistance
  • Minimum ripple at the output
  • Fast response
  • ABS DIN rail mounting
  • Generating/Transmission Distribution stations
  • Building management
  • Load Dispatch center
  • Power Equipment’s OEMs
  • HT/LT Panels
  • Substation Automation
  • SCADA
  • Local and Central monitoring systems

Multi Function Transducer

Applications for Tranducers

  • Fully programmable device
  • Measure voltage, current, frequency and power factor
  • Programmable output: Max 4 analog and 2 digital
  • Standard RS485 modbus communication
    (optional ethernet modbus TCP/ IP)
  • PC based configuration software
  • Up to 30 parameter can be mapped to analog output
  • Analog o/p accuracy as per IEC60688
  • Accuracy class 0.5s/ 0.2s as per IS14697/ IEC 62053-22 for energy
  • LCD with back-lit to display various parameters (optional)
  • Energy/ building management
  • HT/ LT panels
  • Process equipment
  • Motors
Multi Function Transducer

MFT

Have you Any Query? Don't be hesitate.

Feel free to contact, We Are Just One Step far to Give You Perfect Solution.
Contact Us

Contact Us

Office: Shed No. 15A, HSIIDC, Industrial Area, Sector-31, Faridabad – 121003 (India)

Branch: 4th Floor, RudraArcade, Plot No -12, Nainital Road, Rudrapur, Uttarakhand- 263153

0129-432 4296

9971376176, 9811193578, 9560182145

sales@advantechcontrol.com